�ө|�����ѥ��������q

ISO 5660, ASTM E 1354 ���@�q���� ISO 5660, ASTM E 1354

ISO 5660, ASTM E 1354

���@�q���� ISO 5660, ASTM E 1354

Cone Calorimeter ISO 5660, ASTM E 1354

廠牌:�N�z
供應商:�j�x�_�y�ݻ����������q
聯絡電話:02-2531-0981
定價:與我們聯絡

快速詢價

7627

行動條碼QR Code
���@�q���� ISO 5660, ASTM E 1354-��ʱ��XQR Code

�@�ζq����

 

ISO 5660�ABS476��15�����AASTM E 1354�AASTM E 1354�AASTM E 1550�AASTM E 1740�AASTM D 5485�AASTM D 6113�ANFPA 271�ANFPA 264�ACAN ULC 135

 

�W��P�\��

• 0.05g����v������׺٭��ǷP��

• 5000W Inconel�ު��[����

• PID�ūױ���

• �����I����

• �˫~�B�n

• �p����۰ʳ]�m���q�q

• �n�A���ޡA�ժO�A���αļ˱��Y�M�Ʈ𭷾��������׿����c

• �ܳt������

• �˫~�[�]���׿��^

• �������q�t��

  ? �󦻹p�g����

  ? �۰ʮշǩM�Y��

 

• �����R��

  ? ���ϩ�

  ? 0-25�H�d��

 

• �n�A���ޡA�ժO�A���αļ˱��Y�M�Ʈ𭷾��������׿����c

• ����ļˤ��R�t��

• CO 2���R��

  ? �D�������~�u

  ? 0-10�H�d��]v / v�^

  ? CO2���R��

  ? 0-1.0�H�d��]v / v�^

 

• �ƾڮշǩM���i

• ����׼ƾڱĶ�

• �̤p���y�t�v–�C��4�����y�I�����W�̧֪�

• ²�ƪ��۰ʮշdzn��

• Microsoft Excel�u�@ï�����ƾڿ�X

• �Τ�w��p��A�ϧΥͦ��M���i

 

�޳N�ƾکM�n�D

�q��G230 volts 50/60 Hz – 45 Amp – �B�w 7500 Watts

���ҷūסG�u�@�ū�10°C��35°C

 

��������G

 

���J�GISO 5660�зǭn�D���J�շǮ��骺�«צܤ֬�99.5�H�C

�s������J��~�W���ո`����������H�C����20�ɪ��t�״������O�A�޸����O�i�ո`��0 – 430 kPa�]0 – 60 psig�^�C

�b�@���q�����ոն��q�A�bSTP�]�Y��800�ɡ^�U�A�������������J�H�ܤ�40�������t�׿U�N�A�U�N�t�׬��C����20�ɡC

��󥿱`���u�@���]�C��շǡ^�A�w�p�C�Ӥu�@��ϥ�30��100�ɥ��J�C

 

�����R���k�s����G�������ѵL����H�Ϯ����R���k�s�C�Ӻ޽u��������H��103 kPa�]15 psig�^���嫬�޽u���O���ѳ̤j7 l / min���y�q�C

��𥲶�������A�M��~��q�L�����R���C�o�i�H�q�L�ϥΥ]�t���꾯�]�Ҧp�w�����s���ƩΧ󴫪������^���b�u���ЬW�ӳ̻��P�a��{�C

 

�Ѥ��G�@�ζq�����ݭn�N�o���Ѽ��q�q���M�N���ϥΡC�o�O�@�ӫD�`�p���y�{�C�p�G���u���O�i��|�Ө��j�󦹭Ȫ��i�ʡA�h�����Ѥ@�ӳ]�w��250 kPa�]35 psi�^�����O�ո`���C

�u�n�N�o���M��B�i����A�N�i�H�����q�D�q��������N�o���C�����C��25°C�C�ٻݭn�Ƥ��ޡC

 

�ؤo�G1830mm�]W�^x 2650mm x�]H�^x 1150mm�]D�^

 �B�魫�q– 550����

 

�ƷϡG�Ʒϯ�O��50 l / s

 

cone050918-008-1024x768.jpg

conecal3.jpg

 


 

Cone Calorimeter

 

ISO 5660, BS476 PART 15, ASTM E 1354, ASTM E 1354, ASTM E 1550, ASTM E 1740, ASTM D 5485, ASTM D 6113, NFPA 271, NFPA 264, CAN ULC 135

 

Specification & Features

•High Accuracy Weigh Cell with 0.05g resolution

•5000W Inconel Tubular Heater

•PID temperature control

•Spark Igniter

•Specimen shield

•Computerised automated setting of heat flux level

•All stainless steel construction of Hood, ducting, orifice plate, ring sampling probe, and exhaust blower

•Variable speed blower

•Specimen holders (stainless steel)

•Smoke measuring system ?Helium-neon laser light source

?Auto calibration and scaling

 

•Oxygen analyzer ?Paramagnetic

?0-25% range

 

•All stainless steel construction of Hood, ducting, orifice plate, ring sampling probe, and exhaust blower

•Gas sampling and analysis system

•CO 2 analyser

?Non-dispersive infra-red

?0-10% range (v/v)

?CO 2 analyser

?0-1.0% range (v/v)

 

•Data Calibration and Reporting

•High Accuracy Data acquisition

•Minimum Scan rate – 4 scans per second! Fastest on the market

•Simplified Auto-calibration software

•Data output in Microsoft Excel workbook

•User customisation of calculations, graph generation and reporting

 

Technical Data & Requirements

Electrical: 230 volts 50/60 Hz – 45 Amp – Nominal 7500 Watts

 

Ambient Temperature: Operating 10°C to 35°C

 

Gas Supplies:

 

Methane: The ISO 5660 standard requires the methane calibration gas to be of at least 99.5% purity.

 

The regulator attached to the methane cylinder must be capable of supplying 20 litres per minute with an adjustable line pressure of 0 – 430 kPa (0 – 60 psig).

 

During the Cone Calorimeter’s commissioning stages, enough methane should be available for at least 40 minutes of burning at 20 litres per minute at STP (i.e. approximately 800 litres).

 

For normal working practice (daily calibration), expect to use between 30 and 100 litres of methane every working day.

 

Oxygen Analyser Zero Gas: Oxygen-free’ nitrogen must be available to zero the oxygen analyser. The line must be capable of supplying a maximum of 7 l/min with typical line pressures of about 103 kPa (15 psig).

 

The nitrogen must be dried before being passed through the oxygen analyser. This is most easily achieved by the use of an in-line column containing a desiccant such as silica gel regularly reactivated or replaced.

 

Water supply: The Cone Calorimeter requires cooling water for the heat flux gauge and the cold trap. It is a very minimal flow; a pressure regulator set at 250 kPa (35 psi) should be provided if the mains pressure is likely to undergo surges greater than this value.

 

Cooling water may be taken directly from the mains supply provided that it is clean and controllable. The water should be cooler than 25°C. A drain line is also required.

 

Dimensions: 1830mm (W) x 2650mm x (H) x 1150mm (D)

 Shipping weight – 550 Kg

 

Fume extraction: Hood capable of 50 l/s evacuation

 

 

 

 

您也可能對以下商品有興趣...

產品關鍵字:

�ө|�����ѥ��������q

最新廠商動態!

�ө|��������� Picarro ���q���v���x�W���Υb���������첣�~���W�a�P��κ��תA��
���D��/���i�c���L�h�𾯩M WAK AquaClean �P�ū~�W�C����
OMEGA ENGINEERING �FOMEGA�N�z�F���q�����Y�F���q���u�F�P�Žu�F���N�F�F
WHATMAN�N�z�Ů�ļ��o�ȡF�����ֺ��o�ȡFG/A GF/B GF/C�[�����L�o�����F 2020 Cytiva�N�zWhatman�o���ίӧ��F
���׿��T�h�����F���׿��G�h�����F����DZ����F�w��P�~���ߡF

更多

最新儀器!

�s���Ǧ������q

Copyright © 2006-2017 tw17 All rights reserved.
Design: 台灣儀器網

�x�W������Tw17 ��ʱ��XQR Code