廠牌:代理
供應商:大台北尖端儀器有限公司
聯絡電話:02-2531-0981
快速詢價 |
水平燃燒性試驗箱
FAR第25部分App F第I部分,BSS 7230,FMVSS 302,ISO 3795,ASTM D 5132
HFC水平燃燒性試驗箱用於各種材料的防火測試,包括FMVSS 302 –交通部–所有汽車乘員艙中材料的前½”深度,ISO 3795,大眾TL 1010,FAA – FAR部分 25附錄F第1(b)(5)部分–飛機和波音BSS 7230 F3和F4內部艙室中使用的某些材料。
該試驗箱還可用於未經認證的FAR水平可燃性測試。
測試在插入樣本後自動開始。 火焰衝擊時間是可調的,可以編程到控制器中,並在所需時間終止測試火焰。 透過簡單的向上和向下按鈕進行調整。 數字計時器記錄總燃燒時間,然後將其用於計算燃燒率。
規格及特點:
• 由優質拉絲不銹鋼製成
• 可移動的前鋼化玻璃窗,方便取放
• 可移動的室頂,有助於定期清潔
• 不銹鋼樣品架,定制燃燒器,還包括合適的阻火器
• 選配包括用於不支持樣品的各種U形樣品架(帶或不帶0.25mm直徑的線)和用於測量火焰溫度的熱電偶c / w 數字儀表
• 火焰模式,用於預測試火焰穩定
• 根據ISO 3795定制點火源
• 可選的自動火焰施加時間
• 透過樣品插入自動開始測試
• 數字計時器記錄總燃燒時間,然後用於計算燃燒率
• 啟用“火焰後”和“滴落”時間的記錄
• 樣品架和固定式燃燒器,配有燃氣導向管
技術數據和要求:
電氣:230 V AC,50 Hz或115 V AC 60 Hz
氣體:以0.2 bar(2.5 PSI)供應的甲烷氣體
環境溫度:工作溫度10°C至35°C
尺寸:580 mm (W) x 400 mm x (H) x 260 mm (D)
包裝重量:50Kg
Horizontal Flammability Test Chamber
FAR Part 25 App F Part I, BSS 7230, FMVSS 302 , ISO 3795, ASTM D 5132
The HFC Horizontal Flammability Test Chamber is used in various areas of fire testing of materials, including FMVSS 302 – Department of Transportation – First ½” depth of materials in occupant compartments of all motor vehicles, ISO 3795, Volkswagen TL 1010, FAA – FAR Part 25 Appendix F Part 1(b)(5) – Some materials used in interior compartments of air planes and Boeing BSS 7230 F3 and F4.
The chamber can also be used for non-certified FAR horizontal flammability testing.
The test commences automatically on specimen insertion. Flame impingement time is adjustable and is programmed into the controller and terminates the test flame at the desired time. It is adjusted by a simple up and down button. The digital timer records total burning time, which is then used to calculate burn rate.
Specification & Features:
•Fabricated from high quality brushed stainless steel
•Removable front toughened glass window for easy access
•Removable chamber roof to aid periodic cleaning
•Stainless steel specimen holder, bespoke stationary burner and also includes suitable flame arrestor
•Options include various U-frame specimen holders, with or without 0.25 mm diameter wire, for non-supporting samples and a thermocouple c/w digital meter to measure flame temperature
•Flame mode for pre-test flame stabilisation
•Bespoke ignition source according to ISO 3795
•Selectable and automated flame application time
•Automated start of test by sample insertion
•Digital timer records total burning time, which is then
used to calculate burn rate
•Enables “after flame” and “dripping” timings to be recorded
•Specimen holder & stationary burner, complete with gas
pilot tube
Technical Date & Requirements:
Electrical: 230 V AC, 50 Hz or 115 V AC 60 Hz
Gas: Methane gas supplied at 0.2 bar (2.5 PSI)
Ambient Temperature: Operating 10°C to 35°C
Dimensions: 580 mm (W) x 400 mm x (H) x 260 mm (D)
Packed weight: 50Kg